Should you need to leave your Paloma gas geyser unused for a long period of time, you should drain it and turn off all power. This is especially relevant for holiday homes or where there is a risk of water freezing in the pipes, due to non-use.
Information on how to turn off your water heater, drain it and turn it back on is all found in your use and care manual. A Summary is found below:
Should you just be going away from your main home, for a short period of time. You can leave the geyser on and just turn the controller off, by pressing the on/off button on the front panel.
How to turn off your gas geyser off:
- Turn off the controller by pressing the on/off button on the front panel. You will know it is off as all the lights on the control panel will be off.
- (1) Close the gas valve to ensure no gas is going to the water heater.
- (2) Unplug the electrical supply from the wall. (Drain if necessary – see below)
- (3) Close the cold-water isolation valve at the inlet to the water heater.
- If using bottled gas, close off the gas supply at the regulator
Should there be a risk of freezing conditions while the heater is not in use, the gas water heater should be drained to prevent any damage.
How to drain your gas geyser:
- Follow the instructions to turn off your gas geyser, above.
- (4) Open a few hot taps (preferably a shower outlet for higher water flow).
- (5) Unscrew the 2 drain plugs, there is one for the cold-water inlet and one for the hot water outlet, found on the underside of the water heater.
- Let all the water drain from the water heater.
- When the water has stopped flowing, close the hot tap.
- Store the drain plugs in a safe convenient place until you need to use the geyser again.
How to turn on your gas geyser:
- If the water heater was previously drained, screw in the drain plugs at the cold-water inlet and hot water outlet
- Open ALL of the hot taps in the house (make sure there are no plugs plugged in)
- At the inlet to the water heater, open the cold-water isolation valve, fully. This will force air out of the taps
- Close each tap as the water flows freely from it
- Open the gas isolation valve fully at the inlet to the water heater
- If using LPG, open the gas supply SLOWLY at the regulator
- Plug in the plug at the electrical supply point
- Switch on the electrical supply
- Turn on the controller, if using, by pressing the on/off button.
- Test that hot water flows from a hot water tap
A note about the Frost Protection
All Paloma Gas Water Heaters have built-in frost protection. The frost protection system will protect the water heater from damage, by preventing ice from forming in the waterways of the water heater, in the event of freezing conditions. However, it is only operable when the water heater has power going to it. That is why it is best to drain the geyser and pipes, if possible, should freezing temperatures be an issue and you are leaving your geyser unattended for a period of time. Should the geyser be damaged due to freezing temperatures and the power was not on, any damage will not be covered under warranty.
It is also advisable to adequately insulate any pipework to and from the geyser to prevent freezing, as the frost protection does not cover any of the adjoining pipework.
It is not suitable for a Paloma Gas Geyser to be installed in areas where the ambient temperature falls below -20°C – (including wind chill factor).